Frequently Asked Questions

All Hochiki Products have downloadable spec sheets in PDF format located on the Hochiki America website: www.hochiki.com. Go to Products page.

Q: What is the Hochiki America warranty policy?
A: Hochiki's warranty policy, terms, and conditions are printed on the back of every invoice.
Q: Who is the contact in my territory for customer service (United States)?
A: Northeast and Southeast Regions contact Charlotte Duca (714) 670-3228, Pacific and Midwest Regions contact Rocio Castaneda (714) 670-3232.
Q: How do I contact the overseas Hochiki offices?
A: We have links to the Hochiki Japan and Hochiki Europe websites where you can find contact information for each. You can also refer to the Hochiki Worldwide Offices posted on the Hochiki America website: www.hochiki.com.

FireNET Panels

Q: What is the maximum number of loops on the FireNET panel?
A: The panel can be expanded up to 4 SLC Loops.
Q: What agencies is our Fire NET listed in compliance with?
A: NFPA 72 Compliant, UL 864, Local Signaling Unit. S8255 Types: Automatic, manual, water flow and sprinkler supervisory. CSFM: 7165-0410:159
Q: How many onboard NAC circuits does the panel have?
A: There are 4 on board NAC circuits rated at 2.5 Amps each.
Q: Are there any other colors available for the FireNET panel?
A: Yes, Charcoal
Q: My strobes are not flashing correctly when there is an alarm, what do I do?
A: Check the output pattern: The default NAC pattern is temporal. The strobe circuits require a continuous (Steady) output pattern. From the " Access Level 3 " menu, choose " Edit Configuration " then choose " Edit I/O ". Select " Edit Panel I/O ", then " Edit Default Pattern ". Use the up and down arrow keys to highlight the selected pattern, then press the Enter button.
Q: Can I order extra keys for the Fire NET panel?
A: Yes, spare key switch model are FN-SKDK/FN-SKCK. Use this part number when ordering; 0100-03380. This includes one key for the door, and one key for the enable key switch.

HCP-200 & 1000 Series Panel

Q: How many onboard NAC circuits are on the HCP-204 Control Panel?
A: There are 2 NAC circuits 1.75 Amps maximum per circuit
Q: What are the maximum total zones on the HCP-1008 control panel?
A: There is a maximum of 64 zones on the HCP-1008 control panel. Refer to the installation manual for additional information: HCP-1000_SERIES_MANUAL.pdf
Q: What is the different between the HDACT-100U vs. HDACT-100A Digital dialer?
A: The HDACT-100A only transmits general alarm and trouble. The HDACT-100U transmits alarm, trouble, and by zones.

Detectors & Bases

Q: How many LED's are on a smoke detector?
A: There are 2 LED's for 360 degree visibility.
Q: How do I check compatibility of a detector with a base?
A: Refer to the UL Compatibility List: UL_DEVICE_COMPATIBILITY_LISTS.PDF
Q: Questions on compatibility listing for our detectors and bases with other panel manufacturer.
A: The customer is referred to the website www.hochiki.com, go to UL_DEVICE_COMPATIBILITY_LISTS.PDF
Q: What test equipment should be used to test conventional smoke detectors?
A: TSE-A100 smoke pole tester is used to test (alarm) the smoke detector.
Q: How long can a smoke pole extend to?
A: Extends from 5.25 feet to 14.1 feet. Refer to spec sheet for more information Products
Q: Where can I find the sensitivity range for a smoke detector?
A: Refer to the back label of the detector.