| Analog » Alarm C.P. Acc. | FNP-LEDGraphix LED Display |
STANDARD FEATURES - Available in Red and Charcoal Gray
- Up to 504 LED's can be controlled with FireNET Plus Panel
- Available in 3 different size enclosures
- LED's comes in 3 different colors: Red, Green, or Yellow
- FNP-LED can be easily upgraded onsite with minimal cost and effort
| FireNET Graphix SoftwareFireNET Graphix Software Package |
STANDARD FEATURES - Choice of text, graphic, and event list display when event occurs
- Versatile event analysis
- Total history archive
- Easy to program
- Secure System
- Cost effective compared to other systems
- Simple to use
- Unlimited map linking
- Display and control for multiple panels
- Event history can be viewed, filtered and exported to text or HTML documents
| FN-LCD-N (9th Edition)LCD Network Annunciator |
STANDARD FEATURES - UL 864 9th edition approved
- 320 character liquid crystal display (8 line x 40 character)
- LED indicators for Fire, Supervisory Alarm, Pre-Alarm, Fire Output Active, Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble
- Dual RS-485 ports for primary fire network
- RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 16 FN-4127-IO boards
- 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
- 4 on board programmable Form C relays rated at 1 Amp at 30VDC (Fire, Supervisory, Trouble & Auxiliary)
- Same controls as the FireNET fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
- Local piezo sounder for event notification
- Supports user codes & firefighter key to enable access & controls
- Powered by FireNET Aux 24VDC or UL fire listed Aux. 24VDC supply
- Available in red or charcoal, and can be surface or flush mounted (using trim ring)
- True network annunciator, any or all panels can be routed to the FN-LCD-N. In addition, each event category can be individually routed to the FN-LCD-N
- Up to 64 FireNET panels & FN-LCD-N\'s can be networked together in any combination
- 500mA of auxiliary power available rated at 24VDC
- Auto-learn feature
- Built-in help & alarm information screens
- Fire Drill function
- Each FN-LCD-N is completely independent
- Supports up to 32 FN-4127-IO boards on RS485 expansion port
- The FN-LCD-N can be configured to remote reset, silence, resound, any or all panels on the network in any combination
| FN-LCD-S (9th Edition)Serial Annunciator |
STANDARD FEATURES - UL 864 9th edition approved
- Large 320 character liquid crystal display (8 line x 40 character) allows viewing of system status
- LED indicators for Fire, Supervisory Alarm, Pre-Alarm, Fire Output Active, AC Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble
- Same controls as the FireNET fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
- Up to 15 FN-LCD-S serial annunicators may be connected to a FireNET control panel or network annunciator
- Resides on the FireNET slave RS-485 line
- Local piezo sounder for event notification
- Supports user codes & firefighter key to enable access & controls
- Powered by FireNET Aux 24VDC or UL fire listed Aux. 24VDC supply
- Available in red or charcoal, and can be surface or flush mounted
- Built-in help & alarm information screens
- Fire Drill function
| FN-4127-IO16 Channel Input/Output Board |
STANDARD FEATURES - 16 channels of input/output points
- 32 I/O boards per FireNET panel (512 channels of input/output points)
- Each channel configurable as input or output point
- Inputs are opto-isolated non-supervised pulldown type triggered by
- Outputs are open collector transistor pulldown type (100mA max each) that provide
- Simple 4 wire connection to control panel (2 for power, 2 for data)
- All inputs/outputs can be assigned to global functions, any event category, and used in network wide Cause & Effect logic
- Can be mounted locally within control panel enclosure or remotely via FN-ACC accessory enclosure up to 4000ft from the panel
- Each I/O board has a unique address 1-32 (set via DIP switch) on the I/O Comms Bus
- Input/Outputs are for secondary use, not for primary fire initiation inputs or notification outputs
- Two LED\'s are provided for communication status
| FNP-1127-SLCSingle SLC Loop Expander |
STANDARD FEATURES - Adds one SLC loop to the FireNET Plus (FNP-1127E series) control panel
- The SLC loop is capable of 127 sensors/modules, plus 127 analog sounder bases, for a potential total of 254 addresses
- The FireNET Plus 1127E control panel supports one FNP-1127-SLC, for a total of two SLC loops per panel
- Supports Class A and B wiring methods per NFPA 72 Styles 4, 6, and 7 (Style 7 requires isolators)
- Fully supervised & power limited SLC loop
- Supports Hochiki's DCP (Digital Communication Protocol)
- Same functionality as built-in loop of FireNET Plus control panel
- Uses standard wire; shielded/twisted pair is not required on SLC loops
| FN-4127-SLCDual SLC Loop Expander |
STANDARD FEATURES - Adds two SLC loops to a two loop FireNET control panel
- Each SLC loop is capable of 127 sensors/modules, plus 127 analog sounder bases, for a potential total of 254 addresses per loop (127+127 per loop)
- FN-4127-SLC can be added at the factory or installed in the field
- Supports Class A and B wiring methods per NFPA72 Styles 4, 6, and 7 (with isolators)
- Fully supervised & power limited SLC loops
- Supports Hochiki's DCP (Digital. Communication Protocol) loop protocol
- Same functionality as built-in SLC loops of FireNET control panel
- One SLC expander (maximum) may be added per FireNET control panel
- Each SLC loop is completely independent and autonomous
- Uses standard wire, no shielded or twisted pair required on SLC loops
STANDARD FEATURES - Integrates Fire Alarm Control Panel EOL device into module for supervision of interface wiring
- Interfaces Fire Alarm Control Panels to a Local Energy type City Tie monitoring circuit
- Wide operating voltage
- Power limited operation
- Transient protection
- Terminals accept up to 14 AWG wire
- Mounts to a standard 4 inch electrical back box
| FN-DACDigital Alarm Communicator |
STANDARD FEATURES - Contact ID and SIA reporting formats
- UL 864 9th Edition listed
- Programmable from FireNET control panel or by using Loop Explorer
- Zone or Address (Point) reporting
- Remote upload / download and diagnostic tools
- Backup and Duplicate reporting
- Programmable daily test report interval
- Quick installation in FireNET enclosure
|