Conventional » Alarm Control Panel
HCP-204E (Discontinued)
4-Zone Expandable Fire Alarm Control Panel
STANDARD FEATURES
  • 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits. Expandable up to 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits.
  • 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.7 Amps max. per circuit). Expandable up to 4 Class A/B (Style Z/Y) Indicating Circuits.
  • Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audibles may be configured as Steady, Temporal Code, California Code or March Time.
  • Output for RTI or Remote Annunciators of 24 VDC, 300 mA max, unfiltered
  • Built-in Walk Test operation
  • Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second alarm relay.
  • 6 Amp power supply
  • Easy configuration via DIP switches
HCP-204 (Discontinued)
4-Zone Fire Alarm Control Panel
STANDARD FEATURES
  • 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits
  • 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.25 Amps max. per circuit)
  • Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audible may be configured as Steady, Temporal Code, California Code or March Time
  • Selectable alarm verification on initiating circuits
  • Output for 4-wire resettable regulated smoke power supply of 24 VDC 100 mA maximum
  • Output for RTI or Remote Annunciators of 24 VDC, 300 mA max, unfiltered
  • Built-in Walk Test operation
  • Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
  • 2.75 Amp power supply
  • Easy configuration via DIP switches
HCP-202 (Discontinued)
2-Zone Fire Alarm Control Panel
STANDARD FEATURES
  • 2 Class B (Style B) Initiating Circuits which may be configured as 1 Class A (Style D) circuits
  • 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.25 Amps max. per circuit)
  • Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audible may be configured as Steady, Temporal Code, California Code or March Time
  • Selectable alarm verification on initiating circuits
  • Output for 4-wire resettable regulated smoke power supply of 24 VDC 100 mA maximum
  • Output for RTI or Remote Annunciators of 24 VDC, 300 mA max, unfiltered
  • Built-in Walk Test operation
  • Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
  • 2.75 Amp power supply
  • Easy configuration via DIP switches
HCP-1008E
8-Zone Expandable Fire Alarm Control Panel
STANDARD FEATURES
  • 8 Class B (Style B) Initiating Circuits which may be configured as 4 Class A (Style D) Circuits. Expandable up to 24 Class B or 12 Class A Initiating Circuits.
  • 4 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.7 Amps max. per circuit)
  • Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audible may be configured as Steady, Temporal Code, California Code or March Time.
  • Each Initiating Circuit can be configured as Alarm, Supervisory, Waterflow or Trouble
  • Two outputs for 4 wire resetable smoke power supply (200 mA max. each)
  • Alarm verification on Initiating Circuits
  • Easy configuration via push buttons and SLIDE switches on the front panel