| Conventional » Alarm C.P. Acc. | HDM-1008Eight initiating Circuit modules |
STANDARD FEATURES - Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuits which can be configured as Alarm Supervisory, Waterflow or Trouble Circuits
- Bi-Colored Alarm/Supervisory and Trouble LED provided for individual annunciation of each zone
- Slide-in labels for zone identification
- Programmable as Supervisory Circuit for Latching and Non-Latching
- All circuits are power limited for use with limited energy cable
- Removable terminal blocks for ease of wiring and servicing
- Extensive transient protection of all circuits
| HRAM-208Remote Annunciator |
STANDARD FEATURES - 8 Bi-Colored LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber) to match the Series 200 Fire Alarm Control Panels
- Signal Silence, Buzzer Silence, Lamp Test and System Reset switches
- LEDs for A.C. On, Common Trouble and Signal Silence
- Equipped with a keyswitch which allows for enabling and disabling of the Common Control functions
- Each point can be identified by the corresponding label beside the LED
- Mounts in a standard 4-gang electrical box
- Up to three HRAM-208 Remote Annunciators can be used with the HCP-204 and HCP-204E Fire Alarm Control Panels
| HSGM-1004Four Indicating Circuit Module |
STANDARD FEATURES - Four Class A/B (Style Z/Y) Indicating Circuits
- Each Indicating Circuit is rated at 1.7 Amps
- Each Indicating Circuit can be configured as Non-Silenceable (Steady) or Silenceable
- Outputs resound on subsequent alarm
- LEDs (amber) provided for indication of Indicating Circuit trouble
- Programmable to any input circuit
- All circuits are power limited for use with limited energy cable
- Removable terminal blocks for ease of wiring and servicing
- Extensive transient protection of all circuits
| HRA-1000Annunciator Adder Modules |
STANDARD FEATURES - Large capacity of annunciation
- Bi-Colored LEDs
- Slide-in labels for each display point
- Sealed membrane-like buttons and LED indicators
- Each annunciation point is automatically selected for either Alarm (Red) or Supervisory (Amber) to match the HCP-1000 Fire Alarm Panel configuration
- LEDs for A.C. On, Common Trouble, Remote Failure, Aux, Disconnect, Acknowledge, General Alarm, Signal Silence and Test/Config Mode
- Controls for System Reset, Lamp Test, Fire Drill, Aux. Disconnect, Buzzer Silence, Signal Silence, General Alarm and Acknowledge
- Three sizes of enclosures
| HCP-1000-AccessoriesAuxiliary Modules for "1000" series Panels |
STANDARD FEATURES - HRM-1008 (EIGHT RELAY CIRCUIT MODULE)
- Eight-Relay Circuit Module provides eight programmable Form C relays
- Contains removable terminal blocks for easy wiring and servicing
- HDACT-100/100U (DIGITAL ALARM DIALER MODULE)
- Allows panel to communicate to Central station to report an alarm
- Utilizes SIA and DCS ID protocols
- Must be programmed using the
- HPR-100 (POLARITY REVERSAL & CITY TIE MODULE)
- Allows connection to two different types of monitoring systems
- Capable of transmitting a system
| HCP-200-AccessoriesAuxiliary Modules for "200" series Panels |
STANDARD FEATURES - HDM-204 (INITIATING CIRCUIT MODULE)
- Provides up to four class
- Each circuit can be configured to silence able or non-silence able
- Mounts to the bottom of the chassis
- HRM-204 (AUXILIARY QUAD RELAY MODULE)
- Contains four configurable auxiliary relays
- Each relay is rated for 28 VDC @ 1 Amp
- Mounted on top of any detection module
- HRM-208 (EIGHT RELAY MODULE)
- Provides the HCP-200 series with eight configurable auxiliary relays
- Each relay is rated for 28 VDC @ 1 Amp
- Mounted on top of any detection module
|