| Conventional » Detectors | SLR-835BDirect-Wire Photoelectric Smoke Detector |
STANDARD FEATURES - Low Profile - Only 1.8" high
- 2 or 4 wire on bone and white models
- Highly stable operation, RF/transient protection
- Two built-in power/sensitivity supervision/alarm LEDs
- Non-directional smoke chamber
- Vandal resistant security locking feature
- Removable smoke labyrinth for cleaning or replacement
- Automatic sensitivity window verification function meets outlined requirements in NFPA 72, Inspection, Testing and Maintenance
| SLR-835BHDirect-Wire Photoelectric Heat Smoke Detector |
STANDARD FEATURES - Low Profile - Only 2.375" High.
- 2 or 4 Wire Models
- 135°F Latching Heat Sensor
- Highly Stable Operation, RF/Transient Protection
- Two built-in power/sensitivity supervision/alarm LED's
- Non-Directional Smoke Chamber
- Vandal Resistant Security Locking Feature
- Removable smoke labyrinth for cleaning or
replacement
- Automatic Sensitivity window verification function
meets outlined requirements in NFPA 72,
Inspection,Testing and Maintenance.
| SLR-835Wide Voltage Range Photoelectric Smoke Detector 835V |
STANDARD FEATURES - Flat Response Photoelectric Chamber
- Low Profile - Only 1.8" high (with base)
- 2 or 4 wire base compatibility, relay bases available
- Highly stable operation, RF/Transient protection
- Working Voltage 8.0 ~ 35.0 VDC
- Low standby current, 38mA nominal
- Two built-in power/sensitivity supervision/alarm LEDs
- Non-Directional smoke chamber
- Vandal resistant security locking feature
- Interchangeable on Hochiki America's standard smoke and heat detector bases
- Backwards compatible with Hochiki SLK and SIH detectors
- Meets outlined requirements in the NFPA 72 Inspection, Testing and Maintenance, Chapter 7
| SLR-835HPhotoelectric/Heat Smoke Detector |
STANDARD FEATURES - Low profile, 2.2" high (with base)
- 2 or 4 wire base compatibility, relay bases available
- 135°F latching heat sensor
- Heat sensor protected by a built-in guard
- Highly stable operation, RF/Transient protection
- Low standby current - 45mA at 24VDC
- Two built-in power/sensitivity supervision/alarm LEDs
- When the detector senses that its sensitivity has drifted
Non-directional smoke chamber
- Vandal resistant security locking feature
- Removable smoke labyrinth for cleaning or replacement
-
Automatic Sensitivity window verification function
meets outlined requirements in NFPA 72, Chapter 2& 7,
Inspection, Testing and Maintenance.
| SLR-24VPhotoelectric Smoke Detector |
STANDARD FEATURES - Flat Response Photoelectric Chamber
- Low Profile - Only 1.8" high (with base)
- 2 or 4 wire base compatibility, relay bases available
- Highly stable operation, RF/Transient protection
- Low standby current, 45mA at 24VDC
- Two built-in power/sensitivity supervision/alarm LEDs
- Non-Directional smoke chamber
- Vandal resistant security locking feature
- Built-in magnetic go/no-go detector test feature
- Removable smoke labyrinth for cleaning or replacement
- Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 7, Inspection, Testing and Maintenance
- Compatible with SIJ-24 Ionization Detector
- Backwards compatible with Hochiki SLK and SIH detectors
| SLR-24HPhotoelectric/Heat Smoke Detector |
STANDARD FEATURES - Flat Response Photoelectric Chamber
- Low profile, 2.2" high (with base)
- 2 or 4 wire base compatibility, relay bases available
- 135° F latching heat sensor
- Heat sensor protected by a built-in guard
- Highly stable operation, RF/Transient protection
- Low standby current - 45mA at 24VDC
- Two built-in power/sensitivity supervision/alarm LEDs
- Non-directional smoke chamber
- Vandal resistant security locking feature
- Removable smoke labyrinth for cleaning or replacement
- Automaic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2 & 7, for Inspection, Testing and Maintenance
STANDARD FEATURES - Low profile, 1.8" high (with base)
- 2 or 4 wire base compatibility, relay bases available
- Highly stable operation, RF/Transient protection
- Low standby current, 40mA at 24 VDC
- Two built-in power/alarm LEDs for 360° viewing
- Non-directional smoke chamber
- Vandal resistant security locking feature
- Built-in magnetic detector sensitivity test feature. Meets NFPA 72, Chapter 2 & 7, Inspection, Testing and Maintenance requirements
- Compatible with SLR-24V photoelectric detectors
- Backwards compatible with Hochiki SLK and SIH smoke detectors
| DCD-135-190Fixed Temp/Rate of Rise Detector |
STANDARD FEATURES - Choice of fixed temperature/rate-of-rise 135°F or 190°F Heat Detector
- UL Listed spacing up to 60' by 60'
- 2 or 4 wire base compatibility, relay bases available
- Highly stable operation, RF/Transient protection
- Low standby current, 35mA nominal
- Two built-in power/alarm LEDs for 360° viewing
- Fully Electronic Operation
- Power/Alarm LEDs confirm detector status
- Compatible with Hochiki SLR-24 and SIJ-24 detectors and their bases
| DFE-135/190Fixed Temperature Heat Detector |
STANDARD FEATURES - Choice of fixed temperature 135°F or 190°F
- UL Listed ceiling spacing of 50' by 50' (2,500 square feet)
- Self-Restoring
- Heat element protected by a built-in guard
- Contact Rating of 100mA
- Highly Dependable
- Latching LED base available
| DSC-EARate of Rise Heat Detector |
STANDARD FEATURES - Slim design which combines visual appeal with a high standard of reliability
- Operating characteristics enables a very cost effective solution for the use of heat detectors
- Insignificant supervisory current, which enables an unlimited number of detectors to be connected on the same detection wires
- Latching LED base available
|