[Products]
Conventional » Detectors
SLR-835B
Direct-Wire Photoelectric Smoke Detector
STANDARD FEATURES
  • Low Profile - Only 1.8" high
  • 2 or 4 wire on bone and white models
  • Highly stable operation, RF/transient protection
  • Two built-in power/sensitivity supervision/alarm LEDs
  • Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Removable smoke labyrinth for cleaning or replacement
  • Automatic sensitivity window verification function meets outlined requirements in NFPA 72, Inspection, Testing and Maintenance
SLR-835BH
Direct-Wire Photoelectric Heat Smoke Detector
STANDARD FEATURES
  • Low Profile - Only 2.375" High.
  • 2 or 4 Wire Models
  • 135°F Latching Heat Sensor
  • Highly Stable Operation, RF/Transient Protection
  • Two built-in power/sensitivity supervision/alarm LED's
  • Non-Directional Smoke Chamber
  • Vandal Resistant Security Locking Feature
  • Removable smoke labyrinth for cleaning or replacement
  • Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Inspection,Testing and Maintenance.
SLR-835
Wide Voltage Range Photoelectric Smoke Detector 835V
STANDARD FEATURES
  • Flat Response Photoelectric Chamber
  • Low Profile - Only 1.8" high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • Highly stable operation, RF/Transient protection
  • Working Voltage 8.0 ~ 35.0 VDC
  • Low standby current, 38mA nominal
  • Two built-in power/sensitivity supervision/alarm LEDs
  • Non-Directional smoke chamber
  • Vandal resistant security locking feature
  • Interchangeable on Hochiki America's standard smoke and heat detector bases
  • Backwards compatible with Hochiki SLK and SIH detectors
  • Meets outlined requirements in the NFPA 72 Inspection, Testing and Maintenance, Chapter 7
SLR-835H
Photoelectric/Heat Smoke Detector
STANDARD FEATURES
  • Low profile, 2.2" high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • 135°F latching heat sensor
  • Heat sensor protected by a built-in guard
  • Highly stable operation, RF/Transient protection
  • Low standby current - 45mA at 24VDC
  • Two built-in power/sensitivity supervision/alarm LEDs
  • When the detector senses that its sensitivity has drifted Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Removable smoke labyrinth for cleaning or replacement
  • Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2& 7, Inspection, Testing and Maintenance.
SLR-24V
Photoelectric Smoke Detector
STANDARD FEATURES
  • Flat Response Photoelectric Chamber
  • Low Profile - Only 1.8" high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • Highly stable operation, RF/Transient protection
  • Low standby current, 45mA at 24VDC
  • Two built-in power/sensitivity supervision/alarm LEDs
  • Non-Directional smoke chamber
  • Vandal resistant security locking feature
  • Built-in magnetic go/no-go detector test feature
  • Removable smoke labyrinth for cleaning or replacement
  • Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 7, Inspection, Testing and Maintenance
  • Compatible with SIJ-24 Ionization Detector
  • Backwards compatible with Hochiki SLK and SIH detectors
SLR-24H
Photoelectric/Heat Smoke Detector
STANDARD FEATURES
  • Flat Response Photoelectric Chamber
  • Low profile, 2.2" high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • 135° F latching heat sensor
  • Heat sensor protected by a built-in guard
  • Highly stable operation, RF/Transient protection
  • Low standby current - 45mA at 24VDC
  • Two built-in power/sensitivity supervision/alarm LEDs
  • Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Removable smoke labyrinth for cleaning or replacement
  • Automaic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2 & 7, for Inspection, Testing and Maintenance
SIJ-24
Ion Smoke Detector
STANDARD FEATURES
  • Low profile, 1.8" high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • Highly stable operation, RF/Transient protection
  • Low standby current, 40mA at 24 VDC
  • Two built-in power/alarm LEDs for 360° viewing
  • Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Built-in magnetic detector sensitivity test feature. Meets NFPA 72, Chapter 2 & 7, Inspection, Testing and Maintenance requirements
  • Compatible with SLR-24V photoelectric detectors
  • Backwards compatible with Hochiki SLK and SIH smoke detectors
DCD-135-190
Fixed Temp/Rate of Rise Detector
STANDARD FEATURES
  • Choice of fixed temperature/rate-of-rise 135°F or 190°F Heat Detector
  • UL Listed spacing up to 60' by 60'
  • 2 or 4 wire base compatibility, relay bases available
  • Highly stable operation, RF/Transient protection
  • Low standby current, 35mA nominal
  • Two built-in power/alarm LEDs for 360° viewing
  • Fully Electronic Operation
  • Power/Alarm LEDs confirm detector status
  • Compatible with Hochiki SLR-24 and SIJ-24 detectors and their bases
DFE-135/190
Fixed Temperature Heat Detector
STANDARD FEATURES
  • Choice of fixed temperature 135°F or 190°F
  • UL Listed ceiling spacing of 50' by 50' (2,500 square feet)
  • Self-Restoring
  • Heat element protected by a built-in guard
  • Contact Rating of 100mA
  • Highly Dependable
  • Latching LED base available
DSC-EA
Rate of Rise Heat Detector
STANDARD FEATURES
  • Slim design which combines visual appeal with a high standard of reliability
  • Operating characteristics enables a very cost effective solution for the use of heat detectors
  • Insignificant supervisory current, which enables an unlimited number of detectors to be connected on the same detection wires
  • Latching LED base available